• Home
  • Contact
  •  NL 
  • Login medewerkers
  • mijnUMCG

Publicaties 2018

Print 

2018 annual report of the European Liver Transplant Registry (ELTR) - 50-year evolution of liver transplantation.
Adam R, Karam V, Cailliez V, O Grady JG, Mirza D, Cherqui D, Klempnauer J, Salizzoni M, Pratschke J, Jamieson N, Hidalgo E, Paul A, Andujar RL, Lerut J, Fisher L, Boudjema K, Fondevila C, Soubrane O, Bachellier P, Pinna AD, Berlakovich G, Bennet W, Pinzani M, Schemmer P, Zieniewicz K, Ro​​mero CJ, Simone P, Ericzon BG, Schneeberger S, Wigmore SJ, Prous JF, Colledan M, Porte RJ, Yilmaz S, Azoulay D, Pirenne J, Line PD, Trunecka P, Navarro F, Lopez AV, De Carlis L, Pena SR, Kochs E, Duvoux C;
All the other 126 contributing centers and the European Liver and Intestine Transplant Association (ELITA).
Transpl Int. 2018 Sep 26.

​Trajectories of anxiety and depression after liver transplantation as related to outcomes during 2-year follow-up: A prospective cohort study.
Annema C, Drent G, Roodbol PF, Stewart RE, Metselaar HJ, van Hoek B, Porte RJ, Ranchor AV.
Psychosom Med. 2018 Feb/Mar;80(2):174-183. 

Endothelial Dysfunction in Steatotic Human Donor Livers: A Pilot Study of the Underlying Mechanism During Subnormothermic Machine Perfusion.
Beijert I, Mert S, Huang V, Karimian N, Geerts S, Hafiz EOA, Markmann JF, Yeh H, Porte RJ, Uygun K.
Transplant Direct. 2018 Apr 23;4(5):e345.

Identification and validation of the predictive capacity of risk factors and models in liver transplantation over time.
Blok JJ, Putter H, Metselaar HJ, Porte RJ, Gonella F, de Jonge J, van den Berg AP, van der Zande J, de Boer JD, van Hoek B, Braat AE.
Transplant Direct. 2018 Aug 21;4(9):e382.​

A comparative study of single and dual perfusion during end-ischemic subnormothermic liver machine preservation.
Brüggenwirth IMA, Moore C, Mahboub P, Thijssen MF, E X, Leuvenink HGD, Mandrekar P, Wang X, Kowalik TF, Porte RJ, Martins PN.
Transplant Direct. 2018 Oct 23;4(11):e400.​

Opposite acute potassium and sodium shifts during transplantation of hypothermic machine perfused donor livers.
Burlage LC, Hessels L, van Rijn R, Matton APM, Fujiyoshi M, van den Berg AP, Reyntjens KMEM, Meyer P, de Boer MT, de Kleine RHJ, Nijsten MW, Porte RJ.
Am J Transplant. 2018 Nov 9.

Plasma from Patients Undergoing Liver Transplantation Is Resistant to Anticoagulant Activity of Soluble Thrombomodulin (ART-123).
Burlage LC, Bos S, Adelmeijer J, Sakai T, Porte RJ, Lisman T.
Liver Transpl. 2018 Aug 1. doi: 10.1002/lt.25318.

Rationale and design of TransplantLines: a prospective cohort study and biobank of solid organ transplant recipients.
Eisenga MF, Gomes-Neto AW, van Londen M, Ziengs AL, Douwes RM, Stam SP, Osté MCJ, Knobbe TJ, Hessels NR, Buunk AM, Annema C, Siebelink MJ, Racz E, Spikman JM, Bodewes FAJA, Pol RA, Berger SP, Drost G, Porte RJ, Leuvenink HGD, Damman K, Verschuuren EAM, de Meijer VE, Blokzijl H, Bakker SJL.
BMJ Open. 2018 Dec 31;8(12):e024502.​​

Production of Physiologically Relevant Quantities of Hemostatic Proteins During Normothermic Machine Perfusion of Human Livers.
Karangwa SA, Adelmeijer J, Matton APM, de Meijer VE, Lisman T, Porte RJ.
Liver Transpl. 2018 Aug 19. doi: 10.1002/lt.25290.

The first case of ischemia-free organ transplantation in humans: A proof of concept.
van Leeuwen OB, Ubbink R, de Meijer VE, Porte RJ.
​Am J Transplant. 2018 Aug;18(8):2091. doi: 10.1111/ajt.14869. Epub 2018 Apr 27.

Viability criteria for functional assessment of donor livers during normothermic machine perfusion.
van Leeuwen OB, de Meijer VE, Porte RJ.
Liver Transpl. 2018 Oct;24(10):1333-1335.​

The first case of ischemia-free organ transplantation in humans: A proof of concept.
van Leeuwen OB, Ubbink R, de Meijer VE, Porte RJ.
Am J Transplant. 2018 Aug;18(8):2091. doi: 10.1111/ajt.14869. Epub 2018 Apr 27.

Reply to Letter to the Editor by Patrono et al. (LT-18-211), concerning manuscript: Normothermic Machine Perfusion of Donor Livers Without the Need for Human Blood Products (LT-17-589.R2).
Matton APM, de Vries Y, Porte RJ.
Liver Transpl. 2018 Apr 25. doi: 10.1002/lt.25183. 

Elevated plasma levels of cell-free DNA during orthotopic liver transplantation are associated with activation of coagulation.
von Meijenfeldt FA, Burlage LC, Bos S, Adelmeijer J, Porte RJ, Lisman T.
Liver Transpl. 2018 Aug 31. doi: 10.1002/lt.25329.

Ex situ machine perfusion strategies in liver transplantation.
de Meijer VE, Fujiyoshi M, Porte RJ.
J Hepatol. 2018 Nov 5.​

Hypothermic oxygenated machine perfusion reduces bile duct reperfusion injury after transplantation of donation after circulatory death livers.
van Rijn R, van Leeuwen OB, Matton APM, Burlage LC, Wiersema-Buist J, van den Heuvel MC, de Kleine RHJ, de Boer MT, Gouw ASH, Porte RJ.
Liver Transpl. 2018 Jan 25. doi: 10.1002/lt.25023

Post-transplant Muscle Mass measured by Urinary Creatinine Excretion Rate predicts Long-term Outcomes after Liver Transplantation.
Stam SP, Osté MC, Eisenga MF, Blokzijl H, van den Berg AP, Bakker SJ, de Meijer VE.
Am J Transplant. 2018 May 9. doi: 10.1111/ajt.14926.

Will I receive a liver transplant in time?'; chance of survival of patients on the liver transplant waiting list.
Tieleman M, van den Berg AP, van Hoek B, Polak WG, Dubbeld J, Porte RJ, Konijn C, de Man RA, Hanssen BE, Metselaar HJ.
Ned Tijdschr Geneeskd. 2018;162(0):D2159. Dutch. 

​Ex situ normothermic machine perfusion of donor livers using a haemoglobin-based oxygen carrier: a viable alternative to red blood cells.
de Vries Y, van Leeuwen OB, Matton APM, Fujiyoshi M, de Meijer VE, Porte RJ.
Transpl Int. 2018 Jul 28. doi: 10.1111/tri.13320. 

Pretransplant sequential hypo- and normothermic machine perfusion of suboptimal livers donated after circulatory death using a hemoglobin-based oxygen carrier perfusion solution.
de Vries Y, Matton APM, Nijsten MWN, Werner MJM, van den Berg AP, de Boer MT, Buis CI, Fujiyoshi M, de Kleine RHJ, van Leeuwen OB, Meyer P, van den Heuvel MC, de Meijer VE, Porte RJ.
Am J Transplant. 2018 Dec 26.​